M1. Bench it: power, one motor, a safe stop

Whole task: take a bare control board and one motor from the box to a live bench rig. It powers on safely, reports its drivers, turns a motor, reads the E-stop and a switch, and stops when you cut the power.

Parts

Print timelapses: Plate 0: wrist and E-stop box.

Concepts

How-to

Open these official pages at the step that needs them:

Safety facts that shape the task

The test firmware turns every motor at 1000 steps per second from boot until the power goes off, and no command stops it. #STOP only ends a printout (The test firmware, danger box).

So in M1 the safe stop is the switched mains strip, and the motor sits loose on the bench. Nothing is mounted in a joint yet.

Practice

Done check

On camera, from cold:

  1. Polarity is metered and marked.
  2. The drivers are checked by their DIAG pins.
  3. Power goes on through the switched strip.
  4. The power-on report shows six Connection is: GOOD lines.
  5. The motor turns.
  6. #IO shows about 24000 mV and follows the E-stop as it is pressed and released.
  7. #LIMIT names the switch while it is pressed.
  8. The strip switch stops everything.

This is the build guide's own first check (Firmware and first run, section 1), with only one motor connected.

Settled: one motor is enough. The GOOD or BAD line is an SPI check of the driver module, and the test firmware's open-load printing is commented out (main.cpp, lines 868 to 936). Swap motors only with the 24 V off.

At power-up you should hear clicks and see about 1.5 A drawn at 24 V. If not, disconnect (PAROL6 setup and calibration, from 2:30).

Terms

Video

The M1 video is planned.

Sources

  1. Robot system, PAROL6 docs 1.1 Source Robotics. The arm, the control board and the PC, and the 10 ms packet cycle. Accessed 2026-11-07.

  2. Drives, ratios and resolution, PAROL6 docs 1.1 Source Robotics. 200 steps per turn, 32 microsteps, open loop without encoders. Accessed 2026-11-07.

  3. Connecting, PAROL6 docs 1.1 Source Robotics. GX16 power socket, polarity, the normally closed E-stop and the switch within reach. Accessed 2026-11-07.

  4. Stepper drivers, PAROL6 docs 1.1 Source Robotics. TMC5160 modules, DIAG pin orientation and the four ways to destroy the board. Accessed 2026-11-07.

  5. The test firmware, PAROL6 docs 1.1 Source Robotics. Power-on driver report, the #IO, #LIMIT and #STOP commands and the danger box. Accessed 2026-11-07.

  6. Electronics and wiring, PAROL6 docs 1.1 Source Robotics. The GX16 socket to the XT30 on the board, polarity checked twice. Accessed 2026-11-07.

  7. Firmware and first run, PAROL6 docs 1.1 Source Robotics. The build guide's first bench check, which this milestone's done check follows. Accessed 2026-11-07.

  8. PAROL6 setup and calibration Source Robotics on YouTube. The power-up clicks and current draw to expect, at 2:30. Accessed 2026-11-07.